Applied Sciences, Vol. 13, Pages 2343: Study on Transverse Seismic Response Characteristics of Large Diameter Vertical Double-Layer Overlapping Pipe Jacking in the Soil-Rock Composite Stratum

1 year ago 33

Applied Sciences, Vol. 13, Pages 2343: Study on Transverse Seismic Response Characteristics of Large Diameter Vertical Double-Layer Overlapping Pipe Jacking in the Soil-Rock Composite Stratum

Applied Sciences doi: 10.3390/app13042343

Authors: Lingxiao Ding Guangbiao Shao Jinhua Shang Jianyong Han

The sharp change of stiffness in the soil–rock combination stratum is the weak point in the seismic design of the pipe jacking structure. To study the seismic response characteristics of vertical double-layer overlapping pipe jacking, based on the typical soil–rock combination strata in Jinan, two electric power pipe jacking tunnels of 3.6 m diameter were studied as the research objects, where the upper pipe jacking is located in the soil and the lower pipe jacking is located in the composite stratum of half soil and half rock. The soil–rock-overlapping tunnel system was deemed as a plane strain problem. By using the dynamic time history method and considering the non-linearity of material, the seismic response characteristics of a vertical overlapping pipe jacking tunnel under seismic wave were discussed from five aspects, acceleration response, displacement response, stress response, soil interlayer response and the influence of soil–rock combination stratum. The results indicate that under the action of ground motion, the peak acceleration and relative horizontal displacement of the upper pipe jacking are greater than those of the lower pipe jacking; small pipe jacking spacing will lead to the aggravating earthquake failure effect; due to the stiffness difference, the relative horizontal displacement and stress of pipe jacking structure at the soil–rock interface change abruptly. The vertical double-layer arrangement of the pipe jacking increases the buried depth, and the stratum is prone to be uneven hardness. Therefore, the seismic design and relevant structural measures of large diameter vertical overlapping pipe jacking structure should be strengthened.

Read Entire Article